Description
Part Number: MV-D1
Product Headline: High-performance medium voltage drive designed for demanding industrial applications.
Product Specifications:
- Input: 18-66 pulse diode rectifier bridge
- Output: Multilevel PWM with low-voltage IGBT inverter cells
- Power Range: 160 kW up to 20,000 kW
- Voltage Range: 2.4 kV, 3.3 kV, 4.16 kV, 6.0 kV, 6.6 kV, 10 kV, 11 kV, 13.8 kV
- Motor Type: Asynchronous motor, Synchronous motor, Permanent magnet motors
- THDI: <3 % conforming to IEEE 519-1992
- Input Power Factor: ≥ 0.96 from 20% to 100% of load
- Efficiency at Rated Power: Inverter efficiency is 98.5%; Drive efficiency including input transformer is 96% to 97% depending on the product.
Functions: The ATV6000 medium voltage system delivers:
- Tailored solutions to optimize operational efficiency and investment
- Optimized energy usage and reduced consumption
- Reduced downtime and improved uptime
- Minimized Total Cost of Ownership & increased profitability
- Improved productivity & availability
Facts: Services-oriented Drives:
- Easy access via QR code for online and remote support
- Comfortable usability with the connected 10” Harmony HMI screen, supported by storage oscilloscope function
- Real-time intelligence enabled by native Ethernet and embedded web server
- Fast and easy on-site maintenance operation with proven LV IGBT design
- Modular architecture
- Easy front access design
With EcoStruxure Asset Advisor:
- Continuous monitoring of critical asset health and level of stress
- 360° diagnostics with reports and analysis
- Risk mitigation plan with recommended actions
- Access to 24/7 Schneider Electric service assistance
Energy Management Features:
- Embedded power management with +/- 5% measurement accuracy
- Best Efficiency Point function for pumps
- Lifetime monitoring of energy usage with an inbuilt energy dashboard
- Phase-shifted transformer for reduced THDI input on the grid
- Integrated transformer with galvanic insulation feature
- Low dV/dt inverter providing power without high over-voltage at the motor side
Process Optimization:
- Cell bypass feature
- N+1 and N+2 power cell design for redundancy
- Best Efficiency Point function for pumps
- Tested and validated applicative architecture (TVDA)
- Fully compatible with Schneider Electric EcoStruxure Process Automation Systems (hybrid & DCS systems)
- Internal sensing and measurement of key VSD conditions for predictive maintenance planning
- Dedicated application control (droop control, fan/pump function, etc.)
Tailored Solutions:
- Application experts provide optimized engineering solutions for operational efficiency and investment optimization
- Simplified design process and shortened system implementation time
- High level of customization to fit purpose