Schneider MasterPact NW32H2 Circuit Breaker NW32H13PEDO2.0A 3200A 3 Pole Drawout Without Trip Unit

$ 16,230

Description

Schneider MasterPact NW32H2 Circuit Breaker NW32H13PEDO2.0A 3200A 3 Pole Drawout Without Trip Unit

The Schneider MasterPact NW32H2 circuit breaker is a high-performance air circuit breaker designed for power distribution and protection applications. With a rated current of 3200A, 3 poles, and a drawout mounting style, it provides reliable protection and flexibility for industrial and commercial electrical systems. Built with advanced short-circuit breaking capacity and high durability, it ensures long-lasting operational safety.

Attribute Value
Range MasterPact
Product Name MasterPact NW
Circuit Breaker Name MasterPact NW32H2
Product or Component Type Circuit Breaker
Device Application Power distribution protection
Poles Description 3P
Control Unit Without control unit
Rated Current [In] 3200 A at 40 °C
Performance Type H2 100 kA 440 V AC
Rated Operational Voltage [Ue] 690 V AC 50/60 Hz
Suitability for Isolation Yes, conforming to EN/IEC 60947-2
Selectivity Category Category B
Control Type Push-button
Mounting Mode Drawout
Rated Ultimate Short-Circuit Capacity [Icu] 100 kA at 220/415 V AC 50/60 Hz
100 kA at 440 V AC 50/60 Hz
85 kA at 525 V AC 50/60 Hz
85 kA at 690 V AC 50/60 Hz
Rated Service Breaking Capacity [Ics] 100 kA at 220/415 V AC 50/60 Hz
100 kA at 440 V AC 50/60 Hz
85 kA at 525 V AC 50/60 Hz
85 kA at 690 V AC 50/60 Hz
Rated Short-Time Withstand Current [Icw] 85 kA 1s
75 kA 3s
Rated Short-Circuit Making Capacity [Icm] 220 kA 220/415 V AC 50/60 Hz
187 kA 440 V AC 50/60 Hz
187 kA 525 V AC 50/60 Hz
187 kA 690 V AC 50/60 Hz
Integrated Instantaneous Protection 171…209 kA (DIN in kA peak)
Sensor Rating 1600 A, 3200 A
Rated Insulation Voltage [Ui] 1000 V AC 50/60 Hz
Rated Impulse Withstand Voltage [Uimp] 12 kV
Power Dissipation 670 W
Maximum Breaking Time 25 ms
Maximum Closing Response Time 70 ms
Mounting Support Backplate, Rails
Upside Connection Front, Rear
Downside Connection Front, Rear
Connection Pitch 115 mm
Mechanical Durability 10,000 cycles (without maintenance)
20,000 cycles (with maintenance)
Electrical Durability 5000 cycles at 440 V AC 50/60 Hz (without maintenance)
2500 cycles at 690 V AC 50/60 Hz (without maintenance)
AC-23A: 5000 cycles 440 V AC
AC-23A: 2500 cycles 690 V AC
AC-3: 6000 cycles 440/690 V AC
Height 439 mm
Width 441 mm
Depth 395 mm
Net Weight 90 kg
Standards EN/IEC 60947-1, EN/IEC 60947-2
Certifications CE, CCC, EAC
Protection Rating IP30 (IEC 60529)
Pollution Degree 4 (IEC 60664-1)
Ambient Temperature (Operation) -25…70 °C
Ambient Temperature (Storage) -40…85 °C
Operating Altitude 0–2000 m (without derating)
2000–5000 m (with derating)
Package Type PCE
Units Per Package 1
Package Height 30.5 cm
Package Width 29.5 cm
Package Length 37.5 cm
Package Weight 51.236 kg

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Schneider MasterPact NW32H2 Circuit Breaker NW32H13PEDO2.0A 3200A 3 Pole Drawout Without Trip Unit”

Your email address will not be published. Required fields are marked *