Feature | Details |
---|---|
Output Signal | Standard 2-wire: 4-20 mA / Vs = 12-30 Vdc Optional 3-wire: 0.5-4.5 Vdc / Vs = 10-30 Vdc |
Accuracy | ±0.5% FSO (±1% FSO for pressures ≤45 psi (3 x bar)) |
Response Time | <10 ms |
Insulation | >100 MΩ @ 50V |
Permissible Temperatures | Operating: -40°F to 212°F (-40°C to 100°C) Compensating: 14°F to 176°F (-10°C to 80°C) |
Pressure Port / Housing | 304 SS |
Wetted Parts | Diaphragm: Ceramic (up to 2,900 psi) Seals: NBR, Diaphragm: silicone (over 3,000 psi) |
Current Consumption | 2-wire: 25 mA max 3-wire voltage: 5 mA (short-circuit current 20 mA) |
EMC | EMI: EN50087-1/-2 EMS: EN50082-2 |
Stability | Vibration: 10 g / 5 Hz to 200 Hz Shock: 20 g / 11 ms |
Operation Life | 2 M cycles |
Approval | CE, RoHS |