Description
Product Name: Proline Promass X 300
Part Number: 8X3B
Measuring Principle:
Coriolis
Product Headline:
Highest capacity four-tube flowmeter with a compact, easily accessible transmitter, designed for the highest flow rates and outstanding performance in on/offshore oil and gas applications.
Sensor Features:
- Increased Profit: Single installation point providing premium accuracy for large quantities.
- Multivariable Measurement: Measures flow, density, and temperature simultaneously.
- Space-Saving Installation: No need for in-/outlet runs.
- Nominal Diameter: DN 300 to 400 (12 to 16″).
- Four-Tube System: Low pressure drop with complete exterior design made of 1.4435 (316L).
Transmitter Features:
- Full Access: Access to process and diagnostic information with numerous, freely combinable I/Os and fieldbuses.
- Configurable I/O Functionality: Reduced complexity and variety with freely configurable I/O.
- Integrated Verification: Heartbeat Technology for enhanced reliability.
- Compact Design: Dual-compartment housing with up to 3 I/Os.
Nominal Diameter Range:
DN 300 to 400 (12 to 16″)
Wetted Materials:
- Measuring Tube: 1.4404 (316/316L)
- Connection: 1.4404 (316/316L)
Measured Variables:
Mass flow, Density, Temperature, Volume flow, Corrected volume flow (API tables), Reference density, Concentration
Max. Measurement Error:
- Mass Flow (Liquid): ±0.10 % (standard), 0.05 % (option)
- Volume Flow (Liquid): ±0.10 %
- Mass Flow (Gas): ±0.35 %
- Density (Liquid): ±0.0005 g/cm³
Measuring Range:
0 to 4,100 t/h (0 to 4,520 tn. sh./h)
Max. Process Pressure:
PN 100, Class 600
Medium Temperature Range:
–50 to +180 °C (–58 to +356 °F)
Ambient Temperature Range:
- Standard: –40 to +60 °C (–40 to +140 °F)
- Option: –50 to +60 °C (–58 to +140 °F)
Sensor Housing Material:
1.4404 (316L), offering the highest corrosion resistance
Transmitter Housing Material:
- Standard: AlSi10Mg, coated
- Option: 1.4409 (CF3M), similar to 316L
Degree of Protection:
IP66/67, type 4X enclosure
Display/Operation:
- Display: 4-line backlit display with touch control (operation from outside).
- Configuration: Via local display and operating tools possible; remote display available.
Outputs:
- 3 Outputs:
- 4-20 mA HART (active/passive)
- 4-20 mA WirelessHART
- 4-20 mA (active/passive)
- Pulse/frequency/switch output (active/passive)
- Double pulse output (active/passive)
- Relay output
Inputs:
- Status input
- 4-20 mA input
Digital Communication:
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power Supply:
- DC 24 V
- AC 100 to 230 V
- AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous Area Approvals:
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
Product Safety:
CE, C-Tick, EAC marking
Functional Safety:
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511.
Metrological Approvals and Certificates:
- Calibration performed at accredited facilities (ISO/IEC 17025).
- Heartbeat Technology complies with measurement traceability requirements (TÃœV SÃœD attestation).
- MI-005 (Liquids other than water, Hydrocarbons, LPG, cryogenic).
- MI-002, PTB.
Marine Approvals and Certificates:
LR approval, DNV approval, ABS approval, BV approval, CCS approval
Pressure Approvals and Certificates:
PED, CRN
Material Certificates:
3.1 material, NACE MR0175/MR0103, PMI; welding test according to EN ISO, ASME, NORSOK