Industrial Supply Groups

icons8-usa-96
Your Cart

No products in the cart.

Proline Promass X 300 / 8X3B Coriolis Flowmeter

The Proline Promass X 300 / 8X3B Coriolis Flowmeter is the highest capacity four-tube flowmeter, designed for optimal performance in on/offshore oil and gas applications. With a compact and accessible transmitter, it provides premium accuracy for large quantities while measuring flow, density, and temperature simultaneously. The space-saving design eliminates the need for inlet and outlet runs, accommodating a nominal diameter range of DN 300 to 400. Constructed from 1.4435 (316L) for enhanced durability, this flowmeter ensures reliable operation with a maximum process pressure of PN 100 and a wide temperature range of –50 to +180 °C. The integrated verification and flexible I/O options enhance functionality and ease of use in demanding environments.

Add to Wishlist
Add to Wishlist
Category:
Trust Badge Image

Description

Product Name: Proline Promass X 300
Part Number: 8X3B

Measuring Principle:
Coriolis

Product Headline:
Highest capacity four-tube flowmeter with a compact, easily accessible transmitter, designed for the highest flow rates and outstanding performance in on/offshore oil and gas applications.

Sensor Features:

  • Increased Profit: Single installation point providing premium accuracy for large quantities.
  • Multivariable Measurement: Measures flow, density, and temperature simultaneously.
  • Space-Saving Installation: No need for in-/outlet runs.
  • Nominal Diameter: DN 300 to 400 (12 to 16″).
  • Four-Tube System: Low pressure drop with complete exterior design made of 1.4435 (316L).

Transmitter Features:

  • Full Access: Access to process and diagnostic information with numerous, freely combinable I/Os and fieldbuses.
  • Configurable I/O Functionality: Reduced complexity and variety with freely configurable I/O.
  • Integrated Verification: Heartbeat Technology for enhanced reliability.
  • Compact Design: Dual-compartment housing with up to 3 I/Os.

Nominal Diameter Range:
DN 300 to 400 (12 to 16″)

Wetted Materials:

  • Measuring Tube: 1.4404 (316/316L)
  • Connection: 1.4404 (316/316L)

Measured Variables:
Mass flow, Density, Temperature, Volume flow, Corrected volume flow (API tables), Reference density, Concentration

Max. Measurement Error:

  • Mass Flow (Liquid): ±0.10 % (standard), 0.05 % (option)
  • Volume Flow (Liquid): ±0.10 %
  • Mass Flow (Gas): ±0.35 %
  • Density (Liquid): ±0.0005 g/cm³

Measuring Range:
0 to 4,100 t/h (0 to 4,520 tn. sh./h)

Max. Process Pressure:
PN 100, Class 600

Medium Temperature Range:
–50 to +180 °C (–58 to +356 °F)

Ambient Temperature Range:

  • Standard: –40 to +60 °C (–40 to +140 °F)
  • Option: –50 to +60 °C (–58 to +140 °F)

Sensor Housing Material:
1.4404 (316L), offering the highest corrosion resistance

Transmitter Housing Material:

  • Standard: AlSi10Mg, coated
  • Option: 1.4409 (CF3M), similar to 316L

Degree of Protection:
IP66/67, type 4X enclosure

Display/Operation:

  • Display: 4-line backlit display with touch control (operation from outside).
  • Configuration: Via local display and operating tools possible; remote display available.

Outputs:

  • 3 Outputs:
    • 4-20 mA HART (active/passive)
    • 4-20 mA WirelessHART
    • 4-20 mA (active/passive)
    • Pulse/frequency/switch output (active/passive)
    • Double pulse output (active/passive)
    • Relay output

Inputs:

  • Status input
  • 4-20 mA input

Digital Communication:
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

Power Supply:

  • DC 24 V
  • AC 100 to 230 V
  • AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous Area Approvals:
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC

Product Safety:
CE, C-Tick, EAC marking

Functional Safety:
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511.

Metrological Approvals and Certificates:

  • Calibration performed at accredited facilities (ISO/IEC 17025).
  • Heartbeat Technology complies with measurement traceability requirements (TÃœV SÃœD attestation).
  • MI-005 (Liquids other than water, Hydrocarbons, LPG, cryogenic).
  • MI-002, PTB.

Marine Approvals and Certificates:
LR approval, DNV approval, ABS approval, BV approval, CCS approval

Pressure Approvals and Certificates:
PED, CRN

Material Certificates:
3.1 material, NACE MR0175/MR0103, PMI; welding test according to EN ISO, ASME, NORSOK